prodcut parts
①Twin-screw high-efficiency airend
- Newly developed for industrial vacuum applications. Reliable, efficient and low noise.
- Screw technology is more efficient than other technologies (rotary vane, water ring, etc.).
② Specialized permanent magnet motor
- Using high coercive force and high temperature resistant permanent magnets to ensure 150℃ without demagnetization.
- Built-in PTC temperature protection to prevent demagnetization caused by high temperature due to failure.
③ Specialized inverter
- Synchronous, easy frequency control, good dynamic response performance, can quickly respond to a wide range of adjustment and accurately regulate the vacuum degree.
- VSD regulation start. Smooth start. Reduce the impact on the grid.
④ Imported filters
- American imported filter.
- Equipped with pre-filter design. High dust capacity. 99% filtration efficiency @5micro. Fully guarantee the safe operation of the airend.
⑤ Lube oil cooling system
- Uses dedicated synthetic lubricant with a life expectancy of 8,000 hours.
- Lubricant cools the airend, which is then cooled by the cooler
⑥ Instrumentation and electronic control system
- Using instrumentation and electrical control.
- Indication of exhaust temperature, oil/air separator tank pressure,system vacuum level.
⑦Specialized inlet valve for vaccum application
- Ultra-low throttling loss. Contributing to the overall efficiency of the vacuum pump.
- Automatic adjustment of the valve opening according to the load capacity to automatically maintain the system vacuum within the set range.
⑧ Oil/air separator tank
- Using similar design like air compressor. The oil content of exhaust air is less than 3PPM.
- Tangential air inlet design with baffle plate in the inner skirt to achieve cyclone separation and impact separation effect.
⑨No-loss direct drive
- Using motor direct drive. Rotor speed and motor speed consistent.
- The main motor is connected to the airend with a "C" flange to make the motor and the airend a rigid body and keep the axis in alignment.
Specification
| Model | Maximum Pumping Speed (m³/h) | Ultimate Vacuum (mbarA) | Rated Power (kW) | Noise dB(A) | Inlet Size | Exhaust Size | Weight (kg) | Dimensions (mm) |
|---|---|---|---|---|---|---|---|---|
| SCR 200 VSPM | 202 | 0.35 | 3 | 70±5% | DN50 | DN40 | 400 | 860*770*1069 |
| SCR 300 VSPM | 303 | 0.35 | 4.5 | 70±5% | DN65 | DN40 | 440 | 915*830*1100 |
| SCR 450 VSPM | 423 | 0.35 | 5.5 | 70±5% | DN65 | DN40 | 440 | 915*830*1100 |
| SCR 600 VSPM | 580 | 0.35 | 7.5 | 65±5% | DN100 | DN80 | 730 | 1550*1150*1255 |
| SCR 750 VSPM | 727 | 0.35 | 11 | 65±5% | DN100 | DN80 | 760 | 1550*1150*1255 |
| SCR 900 VSPM | 963 | 0.35 | 15 | 65±5% | DN100 | DN80 | 785 | 1550*1150*1255 |
| SCR 1300 VSPM | 1285 | 0.35 | 22 | 70±5% | DN150 | DN100 | 1240 | 2000*1420*1730 |
| SCR 1800 VSPM | 1751 | 0.35 | 30 | 70±5% | DN150 | DN100 | 1315 | 2000*1420*1730 |
| SCR 2000 VSPM | 1925 | 0.35 | 37 | 70±5% | DN150 | DN100 | 1382 | 2000*1420*1730 |
| SCR 3000 VSPM | 3052 | 0.35 | 45 | 74±5% | DN200 | DN150 | 3850 | 2400*2050*1935 |
| SCR 3900 VSPM | 3863 | 0.35 | 55 | 74±5% | DN200 | DN150 | 3975 | 2400*2050*1935 |
| SCR 4600 VSPM | 4523 | 0.35 | 75 | 79±5% | DN200 | DN150 | 4325 | 3000*2000*1950 |
| SCR 5200 VSPM | 5136 | 0.35 | 90 | 79±5% | DN200 | DN150 | 4150 | 3000*2000*1950 |